Tri-Tronics Clear Label Sensor Set Up

How to set up your Tri-Tronics Clear Label Sensor

PLDR_DiagonalLine

1. Remove a label from the backing substrate before the sensor.

2. On the HMI touchscreen, hold down “Length Set” (Figure 1) until the backing substrate only is positioned in the sensor (Figure 2).

CLS_SetUp_Figure1

CLS_SetUp_Figure2

3. On the label sensor, hold down the “AUTOSET” button until the display on the sensor reads “Gap Set” (Figure 3).

CLS_SetUp_Figure3

4. Again, hold down “Length Set” on the HMI until the next label is positioned in the sensor. If the sensor is set up correctly, check the HMI and confirm that the counter for “Length Set” is increasing and holding the count after you release the “Length Set” button.

5. Lastly, position the next label to dispense no more than 3mm past the end of the peel plate.