How to Train Your Label Sensor
Remove a label before the Label Sensor.
Hold the LENGTH SET button to move labels through the label head.
Release the LENGTH SET button once there is only backing in the Label Sensor.
Press and hold the NORMAL button on the Label Sensor until the green light flashes. (clear label sensors use the "Auto Set Gap" button)
Press and hold the LENGTH SET button once again to adjust the "Flag".
Once there is roughly 3mm (1/8in) of label past the peel plate, release the LENGTH SET button and begin labeling.